{"id":1624,"date":"2020-06-23T16:14:52","date_gmt":"2020-06-23T16:14:52","guid":{"rendered":"https:\/\/riedon.com\/blog\/?p=1624"},"modified":"2020-10-15T07:55:54","modified_gmt":"2020-10-15T07:55:54","slug":"active-shunts-accurately-measure-currents-high-power-industrial-automotive-applications","status":"publish","type":"post","link":"https:\/\/riedon.com\/blog\/active-shunts-accurately-measure-currents-high-power-industrial-automotive-applications\/","title":{"rendered":"Active shunts to accurately measure currents in high-power industrial and automotive applications"},"content":{"rendered":"\n[et_pb_section admin_label=&#8221;section&#8221;]\n\t\t[et_pb_row admin_label=&#8221;row&#8221;]\n\t\t\t[et_pb_column type=&#8221;4_4&#8243;]\n\t\t\t\t[et_pb_text admin_label=&#8221;Text&#8221;]\n\t\t\t\t\t<em><strong>Accurate current measurements at high common-mode voltages are essential to control energy flow and optimize efficiency in high-power industrial systems such as motor drives, uninterruptible power supplies, solar inverters and battery systems, or in automotive systems such as traction inverters in\u00a0<a href=\"https:\/\/www.powerelectronicsnews.com\/?s=electric+vehicles+%28EVs%29\">electric vehicles (EVs)<\/a>.<\/strong><\/em>\r\n\r\nThese high-power systems are subjected to hostile environments such as electrical noise, vibration, mechanical shock, temperature variations and ingress of contaminants. Current measurements, typically measured between 100 A to 1000 A on the power-drive side, also known as the hot side, are galvanically isolated and sent across to the microcontroller (MCU) side, also known as the cold side.\r\n\r\nHowever, a new active shunt technology offers an all-in-one solution that combines highly accurate measurement and isolation in a single package.\r\n<h2><strong>Current-monitoring applications<\/strong><\/h2>\r\nAny application that generates or uses significant amounts of electrical power needs to operate as efficiently as possible; in many cases, this means there will be some form of automatic closed-loop feedback that requires accurate current sensing.\r\n\r\n<strong>Large battery systems have become more prevalent in recent years, providing power to essential buildings such as data centers and hospitals.\u00a0<\/strong>Monitoring battery capacity and usage requires accurate current measurement.\u00a0<a href=\"https:\/\/www.powerelectronicsnews.com\/tag\/motion-control\/\" target=\"_blank\" rel=\"noreferrer noopener\">Motors\u00a0<\/a>are being used more than ever to automate our world; as we move toward more efficient brushless DC motor types, current measurement is an essential aspect of electronic commutation.\r\n\r\nMany high-growth sectors, including renewable energy, EVs and hybrid EVs (HEVs), also require accurate current monitoring for management, reporting and control.\r\n\r\n<iframe loading=\"lazy\" src=\"https:\/\/www.youtube.com\/embed\/eJypc-zgFQg\" width=\"560\" height=\"315\" frameborder=\"0\" allowfullscreen=\"allowfullscreen\"><\/iframe>\r\n\r\nContinue to read <a href=\"https:\/\/www.powerelectronicsnews.com\/active-shunts-to-accurately-measure-currents-in-high-power-industrial-and-automotive-applications\/\">here<\/a>.\n\t\t\t\t[\/et_pb_text]\n\t\t\t[\/et_pb_column]\n\t\t[\/et_pb_row]\n\t[\/et_pb_section]\n","protected":false},"excerpt":{"rendered":"<p>Accurate current measurements at high common-mode voltages are essential to control energy flow and optimize efficiency in high-power industrial systems such as motor drives, uninterruptible power supplies, solar inverters and battery systems, or in automotive systems such as traction inverters in\u00a0electric vehicles (EVs). These high-power systems are subjected to hostile environments such as electrical noise, [&hellip;]<\/p>\n","protected":false},"author":3,"featured_media":1742,"comment_status":"closed","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_et_pb_use_builder":"on","_et_pb_old_content":"<em><strong>Accurate current measurements at high common-mode voltages are essential to control energy flow and optimize efficiency in high-power industrial systems such as motor drives, uninterruptible power supplies, solar inverters and battery systems, or in automotive systems such as traction inverters in\u00a0<a href=\"https:\/\/www.powerelectronicsnews.com\/?s=electric+vehicles+%28EVs%29\">electric vehicles (EVs)<\/a>.<\/strong><\/em>\r\n\r\nThese high-power systems are subjected to hostile environments such as electrical noise, vibration, mechanical shock, temperature variations and ingress of contaminants. Current measurements, typically measured between 100 A to 1000 A on the power-drive side, also known as the hot side, are galvanically isolated and sent across to the microcontroller (MCU) side, also known as the cold side.\r\n\r\nHowever, a new active shunt technology offers an all-in-one solution that combines highly accurate measurement and isolation in a single package.\r\n<h2><strong>Current-monitoring applications<\/strong><\/h2>\r\nAny application that generates or uses significant amounts of electrical power needs to operate as efficiently as possible; in many cases, this means there will be some form of automatic closed-loop feedback that requires accurate current sensing.\r\n\r\n<strong>Large battery systems have become more prevalent in recent years, providing power to essential buildings such as data centers and hospitals.\u00a0<\/strong>Monitoring battery capacity and usage requires accurate current measurement.\u00a0<a href=\"https:\/\/www.powerelectronicsnews.com\/tag\/motion-control\/\" target=\"_blank\" rel=\"noreferrer noopener\">Motors\u00a0<\/a>are being used more than ever to automate our world; as we move toward more efficient brushless DC motor types, current measurement is an essential aspect of electronic commutation.\r\n\r\nMany high-growth sectors, including renewable energy, EVs and hybrid EVs (HEVs), also require accurate current monitoring for management, reporting and control.\r\n\r\n<iframe src=\"https:\/\/www.youtube.com\/embed\/eJypc-zgFQg\" width=\"560\" height=\"315\" frameborder=\"0\" allowfullscreen=\"allowfullscreen\"><\/iframe>\r\n\r\nContinue to read <a href=\"https:\/\/www.powerelectronicsnews.com\/active-shunts-to-accurately-measure-currents-in-high-power-industrial-and-automotive-applications\/\">here<\/a>.","_et_gb_content_width":"","footnotes":""},"categories":[383,411],"tags":[410],"class_list":["post-1624","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-power-resistors","category-smart-sensor","tag-smart-sensor"],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v24.9 - https:\/\/yoast.com\/wordpress\/plugins\/seo\/ -->\n<title>Active shunts to accurately measure currents in high-power industrial and automotive applications - Riedon Company Blog<\/title>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/riedon.com\/blog\/active-shunts-accurately-measure-currents-high-power-industrial-automotive-applications\/\" \/>\n<meta property=\"og:locale\" content=\"en_US\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"Active shunts to accurately measure currents in high-power industrial and automotive applications - Riedon Company Blog\" \/>\n<meta property=\"og:description\" content=\"Accurate current measurements at high common-mode voltages are essential to control energy flow and optimize efficiency in high-power industrial systems such as motor drives, uninterruptible power supplies, solar inverters and battery systems, or in automotive systems such as traction inverters in\u00a0electric vehicles (EVs). These high-power systems are subjected to hostile environments such as electrical noise, [&hellip;]\" \/>\n<meta property=\"og:url\" content=\"https:\/\/riedon.com\/blog\/active-shunts-accurately-measure-currents-high-power-industrial-automotive-applications\/\" \/>\n<meta property=\"og:site_name\" content=\"Riedon Company Blog\" \/>\n<meta property=\"article:published_time\" content=\"2020-06-23T16:14:52+00:00\" \/>\n<meta property=\"article:modified_time\" content=\"2020-10-15T07:55:54+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/riedon.com\/blog\/wp-content\/uploads\/2020\/06\/smart_shunt.jpg\" \/>\n\t<meta property=\"og:image:width\" content=\"2152\" \/>\n\t<meta property=\"og:image:height\" content=\"1124\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/jpeg\" \/>\n<meta name=\"author\" content=\"Frida Hovsepian\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:label1\" content=\"Written by\" \/>\n\t<meta name=\"twitter:data1\" content=\"Frida Hovsepian\" \/>\n\t<meta name=\"twitter:label2\" content=\"Est. reading time\" \/>\n\t<meta name=\"twitter:data2\" content=\"1 minute\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\/\/schema.org\",\"@graph\":[{\"@type\":\"WebPage\",\"@id\":\"https:\/\/riedon.com\/blog\/active-shunts-accurately-measure-currents-high-power-industrial-automotive-applications\/\",\"url\":\"https:\/\/riedon.com\/blog\/active-shunts-accurately-measure-currents-high-power-industrial-automotive-applications\/\",\"name\":\"Active shunts to accurately measure currents in high-power industrial and automotive applications - Riedon Company Blog\",\"isPartOf\":{\"@id\":\"https:\/\/riedon.com\/blog\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\/\/riedon.com\/blog\/active-shunts-accurately-measure-currents-high-power-industrial-automotive-applications\/#primaryimage\"},\"image\":{\"@id\":\"https:\/\/riedon.com\/blog\/active-shunts-accurately-measure-currents-high-power-industrial-automotive-applications\/#primaryimage\"},\"thumbnailUrl\":\"https:\/\/riedon.com\/blog\/wp-content\/uploads\/2020\/06\/smart_shunt.jpg\",\"datePublished\":\"2020-06-23T16:14:52+00:00\",\"dateModified\":\"2020-10-15T07:55:54+00:00\",\"author\":{\"@id\":\"https:\/\/riedon.com\/blog\/#\/schema\/person\/aefbc2f2d2d316159417534612d6dbce\"},\"breadcrumb\":{\"@id\":\"https:\/\/riedon.com\/blog\/active-shunts-accurately-measure-currents-high-power-industrial-automotive-applications\/#breadcrumb\"},\"inLanguage\":\"en-US\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\/\/riedon.com\/blog\/active-shunts-accurately-measure-currents-high-power-industrial-automotive-applications\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\/\/riedon.com\/blog\/active-shunts-accurately-measure-currents-high-power-industrial-automotive-applications\/#primaryimage\",\"url\":\"https:\/\/riedon.com\/blog\/wp-content\/uploads\/2020\/06\/smart_shunt.jpg\",\"contentUrl\":\"https:\/\/riedon.com\/blog\/wp-content\/uploads\/2020\/06\/smart_shunt.jpg\",\"width\":2152,\"height\":1124},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\/\/riedon.com\/blog\/active-shunts-accurately-measure-currents-high-power-industrial-automotive-applications\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\/\/riedon.com\/blog\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"Active shunts to accurately measure currents in high-power industrial and automotive applications\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\/\/riedon.com\/blog\/#website\",\"url\":\"https:\/\/riedon.com\/blog\/\",\"name\":\"Riedon Company Blog\",\"description\":\"Resistors industry blog for manufacturers that use resistors\",\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\/\/riedon.com\/blog\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"en-US\"},{\"@type\":\"Person\",\"@id\":\"https:\/\/riedon.com\/blog\/#\/schema\/person\/aefbc2f2d2d316159417534612d6dbce\",\"name\":\"Frida Hovsepian\",\"image\":{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\/\/riedon.com\/blog\/#\/schema\/person\/image\/\",\"url\":\"https:\/\/secure.gravatar.com\/avatar\/ec2db7b9597d0e8d9b6aaadb6882b301?s=96&d=mm&r=g\",\"contentUrl\":\"https:\/\/secure.gravatar.com\/avatar\/ec2db7b9597d0e8d9b6aaadb6882b301?s=96&d=mm&r=g\",\"caption\":\"Frida Hovsepian\"},\"sameAs\":[\"http:\/\/www.riedon.com\"],\"url\":\"https:\/\/riedon.com\/blog\/author\/friedahovsepian\/\"}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"Active shunts to accurately measure currents in high-power industrial and automotive applications - Riedon Company Blog","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/riedon.com\/blog\/active-shunts-accurately-measure-currents-high-power-industrial-automotive-applications\/","og_locale":"en_US","og_type":"article","og_title":"Active shunts to accurately measure currents in high-power industrial and automotive applications - Riedon Company Blog","og_description":"Accurate current measurements at high common-mode voltages are essential to control energy flow and optimize efficiency in high-power industrial systems such as motor drives, uninterruptible power supplies, solar inverters and battery systems, or in automotive systems such as traction inverters in\u00a0electric vehicles (EVs). These high-power systems are subjected to hostile environments such as electrical noise, [&hellip;]","og_url":"https:\/\/riedon.com\/blog\/active-shunts-accurately-measure-currents-high-power-industrial-automotive-applications\/","og_site_name":"Riedon Company Blog","article_published_time":"2020-06-23T16:14:52+00:00","article_modified_time":"2020-10-15T07:55:54+00:00","og_image":[{"width":2152,"height":1124,"url":"https:\/\/riedon.com\/blog\/wp-content\/uploads\/2020\/06\/smart_shunt.jpg","type":"image\/jpeg"}],"author":"Frida Hovsepian","twitter_card":"summary_large_image","twitter_misc":{"Written by":"Frida Hovsepian","Est. reading time":"1 minute"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"WebPage","@id":"https:\/\/riedon.com\/blog\/active-shunts-accurately-measure-currents-high-power-industrial-automotive-applications\/","url":"https:\/\/riedon.com\/blog\/active-shunts-accurately-measure-currents-high-power-industrial-automotive-applications\/","name":"Active shunts to accurately measure currents in high-power industrial and automotive applications - Riedon Company Blog","isPartOf":{"@id":"https:\/\/riedon.com\/blog\/#website"},"primaryImageOfPage":{"@id":"https:\/\/riedon.com\/blog\/active-shunts-accurately-measure-currents-high-power-industrial-automotive-applications\/#primaryimage"},"image":{"@id":"https:\/\/riedon.com\/blog\/active-shunts-accurately-measure-currents-high-power-industrial-automotive-applications\/#primaryimage"},"thumbnailUrl":"https:\/\/riedon.com\/blog\/wp-content\/uploads\/2020\/06\/smart_shunt.jpg","datePublished":"2020-06-23T16:14:52+00:00","dateModified":"2020-10-15T07:55:54+00:00","author":{"@id":"https:\/\/riedon.com\/blog\/#\/schema\/person\/aefbc2f2d2d316159417534612d6dbce"},"breadcrumb":{"@id":"https:\/\/riedon.com\/blog\/active-shunts-accurately-measure-currents-high-power-industrial-automotive-applications\/#breadcrumb"},"inLanguage":"en-US","potentialAction":[{"@type":"ReadAction","target":["https:\/\/riedon.com\/blog\/active-shunts-accurately-measure-currents-high-power-industrial-automotive-applications\/"]}]},{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/riedon.com\/blog\/active-shunts-accurately-measure-currents-high-power-industrial-automotive-applications\/#primaryimage","url":"https:\/\/riedon.com\/blog\/wp-content\/uploads\/2020\/06\/smart_shunt.jpg","contentUrl":"https:\/\/riedon.com\/blog\/wp-content\/uploads\/2020\/06\/smart_shunt.jpg","width":2152,"height":1124},{"@type":"BreadcrumbList","@id":"https:\/\/riedon.com\/blog\/active-shunts-accurately-measure-currents-high-power-industrial-automotive-applications\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/riedon.com\/blog\/"},{"@type":"ListItem","position":2,"name":"Active shunts to accurately measure currents in high-power industrial and automotive applications"}]},{"@type":"WebSite","@id":"https:\/\/riedon.com\/blog\/#website","url":"https:\/\/riedon.com\/blog\/","name":"Riedon Company Blog","description":"Resistors industry blog for manufacturers that use resistors","potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/riedon.com\/blog\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"en-US"},{"@type":"Person","@id":"https:\/\/riedon.com\/blog\/#\/schema\/person\/aefbc2f2d2d316159417534612d6dbce","name":"Frida Hovsepian","image":{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/riedon.com\/blog\/#\/schema\/person\/image\/","url":"https:\/\/secure.gravatar.com\/avatar\/ec2db7b9597d0e8d9b6aaadb6882b301?s=96&d=mm&r=g","contentUrl":"https:\/\/secure.gravatar.com\/avatar\/ec2db7b9597d0e8d9b6aaadb6882b301?s=96&d=mm&r=g","caption":"Frida Hovsepian"},"sameAs":["http:\/\/www.riedon.com"],"url":"https:\/\/riedon.com\/blog\/author\/friedahovsepian\/"}]}},"_links":{"self":[{"href":"https:\/\/riedon.com\/blog\/wp-json\/wp\/v2\/posts\/1624"}],"collection":[{"href":"https:\/\/riedon.com\/blog\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/riedon.com\/blog\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/riedon.com\/blog\/wp-json\/wp\/v2\/users\/3"}],"replies":[{"embeddable":true,"href":"https:\/\/riedon.com\/blog\/wp-json\/wp\/v2\/comments?post=1624"}],"version-history":[{"count":4,"href":"https:\/\/riedon.com\/blog\/wp-json\/wp\/v2\/posts\/1624\/revisions"}],"predecessor-version":[{"id":1743,"href":"https:\/\/riedon.com\/blog\/wp-json\/wp\/v2\/posts\/1624\/revisions\/1743"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/riedon.com\/blog\/wp-json\/wp\/v2\/media\/1742"}],"wp:attachment":[{"href":"https:\/\/riedon.com\/blog\/wp-json\/wp\/v2\/media?parent=1624"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/riedon.com\/blog\/wp-json\/wp\/v2\/categories?post=1624"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/riedon.com\/blog\/wp-json\/wp\/v2\/tags?post=1624"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}